CIVILICA We Respect the Science
(ناشر تخصصی کنفرانسهای کشور / شماره مجوز انتشارات از وزارت فرهنگ و ارشاد اسلامی: ۸۹۷۱)

Condition Monitoring and Fault Diagnosis of a Boiler Feed Pump of Zargan Power Plant

عنوان مقاله: Condition Monitoring and Fault Diagnosis of a Boiler Feed Pump of Zargan Power Plant
شناسه ملی مقاله: ICIRES06_034
منتشر شده در ششمین کنفرانس بین المللی نوآوری و تحقیق در علوم مهندسی در سال 1399
مشخصات نویسندگان مقاله:

Ahmad Hossein Assefinejad - Saba Power and Energy Group
Hossein Yarahmadi - Saba Power and Energy Group
Mohammad Hassan Kargozarfard - Saba Power and Energy Group

خلاصه مقاله:
The present article highlights an experimental investigation to monitor the vibration condition of the tow boiler feed pumps (B.F.P.) unit, which is a part of the B.F.P. train of a large utility steam power plant. Four bearings support each B.F.P. Three axial measurements were made at bearing supports for 12 weeks. Displacement and velocity were measured along with horizontal, vertical, and axial directions. Based on the vibration analysis, the causes of excessive vibrations were estimated. Remedial measures were applied toensure safer and fault-free operation of the B.F.P. unit

کلمات کلیدی:
Boiler feed pump, Condition monitoring, Vibration analysis.

صفحه اختصاصی مقاله و دریافت فایل کامل: https://civilica.com/doc/1033479/