CIVILICA We Respect the Science
(ناشر تخصصی کنفرانسهای کشور / شماره مجوز انتشارات از وزارت فرهنگ و ارشاد اسلامی: ۸۹۷۱)

Magnetic detection of albuminuria using hematite nanorods synthesized via chemical hydrothermal method

عنوان مقاله: Magnetic detection of albuminuria using hematite nanorods synthesized via chemical hydrothermal method
شناسه ملی مقاله: JR_IJBMS-24-7_013
منتشر شده در در سال 1400
مشخصات نویسندگان مقاله:

Ali Ramzannezhad - Department of Science, Faculty of Imam Mohammad Bagher, Mazandaran Branch, Technical and Vocational University, Sari, Iran
Amir Hayati - Department of Science, Faculty of Imam Mohammad Bagher, Mazandaran Branch, Technical and Vocational University, Sari, Iran
Ali Bahari - Department of Physics, Faculty of Basic Sciences, University of Mazandaran,Sari, Iran
Hamed Najafi-Ashtiani - Department of Physics, Faculty of Science, Velayat University, Iranshahr, Iran

خلاصه مقاله:
Objective(s): Albuminuria is a biomarker in the diagnosis of kidney disease which is due to the presence of high albumin in the urine and is one of the complications of diabetes. In recent years, the methods used to identify albuminuria have been expensive and time-consuming. Furthermore, another problem is the lack of accurate measurement of albuminuria. This problem leads to kidney isolation as well as a decrease in erythropoietin levels. Therefore, the main aim of our work is to design a magnetic nanobiosensor with better sensitivity to detect minimal levels of albuminuria. Materials and Methods: In the present work, we synthesized Hematite Nano Rods (HNRs) using FeCl۳, NaOH and Cetyltrimethylammonium bromide (CTAB) precursors via the hydrothermal method. Then, HNRs were characterized using UV-vis spectroscopy, Fourier Transform Infrared Spectroscopy (FTIR), Transmission Electron Microscopy (TEM) and Vibrating Sample Magnetometer (VSM) techniques.Results: The obtained results from clinical performance of the HNR nanobiosensor show that the magnetization changes of HNR in interaction with the albumin biomarker can determine the presence or absence of protein in biological samples. The accuracy and repeatability of the HNR nanobiosensor from the value of the R۲ coefficient in the standard equation is ۰.۹۷۴۳.Conclusion: We obtained the standard curve through interaction of the HNRs with albumin protein. The standard equation is obtained by plotting the magnetization curve of a non-interacting sample to interacting samples in terms of protein concentration. The Bland-Altman statistical graph prove that the HNR nanobiosensor is as reliable as experimental methods.

کلمات کلیدی:
Albumin, Hematite nanorods, Hydrothermal method, Kidney disease, Magnetic detection

صفحه اختصاصی مقاله و دریافت فایل کامل: https://civilica.com/doc/1252796/