Comprehensive pinch-exergy analyzes of the NGL recovery process

عنوان مقاله: Comprehensive pinch-exergy analyzes of the NGL recovery process
شناسه ملی مقاله: JR_GPJU-10-1_002
منتشر شده در در سال 1401
مشخصات نویسندگان مقاله:

Fakhrodin Jovijari - Department of Mechanical Engineering, Ahvaz branch, Islamic Azad University, Ahvaz, Iran
Abbas kosarineia - Department of Mechanical Engineering, Ahvaz branch, Islamic Azad University, Ahvaz, Iran
Mehdi Mehrpooya - Department of Mechanical Engineering, Ahvaz branch, Islamic Azad University, Ahvaz, Iran / Department of Renewable Energies and Environment, Faculty of New Sciences and Technologies, University of Tehran, Tehran, Iran
Nader Nabhani - Department of Mechanical Engineering, Ahvaz branch, Islamic Azad University, Ahvaz, Iran / Department of Mechanical Engineering, Petroleum University of Technology (PUT), Ahwaz, Iran

خلاصه مقاله:
Energy quality is a very important criterion, which affects the economic growth of that country. In this study, a real-life case study Natural Gas Liquids plant ۸۰۰, from National Iranian South Oil Company located in the southwest of Iran was considered by conventional exergy analysis, advanced exergy analysis, combined pinch and exergy analysis, and combined pinch and advanced exergy analysis methods. The results of conventional exergy analysis illustrate that the highest amount of exergy destruction belongs to compressors and heat exchangers with ۵۱۰ and ۶۲۹ kW respectively. The advanced exergy analysis suggested that the exergy destruction of the heat exchanger and compressor and will reduce by modifying the performance of these components. However, according to this analysis, for (E-۱۰۱) heat exchanger despite having the highest rate of exergy destruction, is not in the priority of modification due to its low level of avoidable exergy destruction. Also, the avoidable, endogenous part of exergy destruction of the compressor (K۱۰۳) and heat exchanger (E-۱۰۲) will reduce by improving the performance of these components. In the following, and by using the combined Pinch and advanced exergy analysis diagram, it was possible to display simultaneously the energy consumptions rate and the unavoidable exergy destruction of the heat exchanging network. According to this graphical analysis, the plant's minimum hot and cold required utilities are equal to ۴۱۱ and ۱۰,۲۱۱ kW, respectively for ΔTmin of ۱۰.۶۴۵ °C. And heat exchanger E-۱۰۲ has more priorities of improvement compared to other heat exchangers.

کلمات کلیدی:
NGL plant, Pinch, Conventional exergy analysis, Advanced exergy analysis, Combined Pinch and exergy analysis, Combined pinch, and advanced exergy analysis