Investigation of the Impact of Catheter Placement in the Hand on Catheter Lifespan inHospitalized Patients

عنوان مقاله: Investigation of the Impact of Catheter Placement in the Hand on Catheter Lifespan inHospitalized Patients
شناسه ملی مقاله: HUMS05_243
منتشر شده در پنجمین کنگره پژوهشی دانشجویان دانشگاه علوم پزشکی هرمزگان در سال 1402
مشخصات نویسندگان مقاله:

Ali safdari - Student Research Committee, Hamadan University of Medical Sciences, Hamadan, Iran
Fatemeh Mehrabi - Department of Internal Surgery Nursing, Faculty of Nursing and Midwifery, Arak University of Medical Sciences, Arak,Iran
Azam Moslami - Assistant Professor, Department of Biostatistics, Faculty of Medicine, Arak University of Medical Sciences, Arak, Iran
Ali Asgari - Department of Internal Surgery Nursing, Faculty of Nursing and Midwifery, Arak University of Medical Sciences, Arak,Iran

خلاصه مقاله:
Introduction: Venous access is one of the most common care procedures for hospitalized patients, typicallyperformed by nurses. The lifespan of a catheter is influenced by various factors. Among them, the principlesrelated to the selection of the appropriate vein and its anatomical placement are of particular importance. Despitethe significance of the anatomical location of the catheter, there is limited conclusive evidence regarding therelationship between the anatomical location of the catheter and its lifespan. Therefore, this study aimed toinvestigate the impact of catheter placement on patient outcomes and catheter lifespan.Methods: This prospective cohort study was conducted in ۲۰۲۲ at four teaching hospitals in Arak City (centralIran). Patients meeting the study criteria, including normal skin condition, absence of coagulopathy, no receiptof chemotherapy drugs, Phenytoin, and calcium gluconate, were enrolled. The catheters placed in Intermediate(median) Basilic (cubital) vein, Cephalic vein, Intermediate antebrachial vein, and Dorsal metacarpal vein werefollowed for ۷۲ hours. Data analysis was performed using SPSS software, utilizing descriptive and analyticalstatistical tests.Results: A total of ۲۹۹ patients were included in the evaluation, with ۵۳.۸% being male. The results showed asignificant difference in catheter lifespan based on anatomical location, with patients who had catheters placedin the Intermediate (median) Basilic (cubital) vein more likely to require replacement within the first ۱۲ hoursof catheter insertion. Additionally, the catheter removal rate in this area was higher.Conclusion: Our study results demonstrate a significant difference in catheter lifespan based on the placementlocation. Patients with catheters placed in the (cubital) vein were more likely to require reinsertion. Despite theeasy access to this vein, its long-term use for catheter insertion faces limitations

کلمات کلیدی:
Peripheral venous catheter, Anatomical location, Catheter lifespan