CIVILICA We Respect the Science
(ناشر تخصصی کنفرانسهای کشور / شماره مجوز انتشارات از وزارت فرهنگ و ارشاد اسلامی: ۸۹۷۱)

Spectral Separation of Quantum Dots within Tissue Equivalent Phantom Using Linear Unmixing Methods in Multispectral Fluorescence Reflectance Imaging

عنوان مقاله: Spectral Separation of Quantum Dots within Tissue Equivalent Phantom Using Linear Unmixing Methods in Multispectral Fluorescence Reflectance Imaging
شناسه ملی مقاله: JR_IJMP-9-3_004
منتشر شده در شماره 3 دوره 9 فصل در سال 1391
مشخصات نویسندگان مقاله:

Ebrahim Najafzadeh - Ardabil University of Medical Sciences, Ardabil, Iran
Marjaneh Hejazi - Medical Physics and Biomedical Engineering Department, School of Medicine, Tehran University of Medical Sciences, Tehran, Iran
Alireza Ahmadian - Medical Physics and Biomedical Engineering Department, School of Medicine, Tehran University of Medical Sciences, Tehran, Iran.
Hanieh Mohamadreza - Bio Optical Imaging Group, Research Center for Molecular and Cellular Imaging, Tehran University of Medical Sciences, Tehran, Iran.

خلاصه مقاله:
Introduction Non-invasive Fluorescent Reflectance Imaging (FRI) is used for accessing physiological and molecular processes in biological media. The aim of this article is to separate the overlapping emission spectra of quantum dots within tissue-equivalent phantom using SVD, Jacobi SVD, and NMF methods in the FRI mode. Materials and Methods In this article, a tissue-like phantom and an optical setup in reflectance mode were developed. The algorithm of multispectral imaging method was then written in Matlab environment. The setup included the diode-pumped solid-state lasers at 479 nm, 533 nm, and 798 nm, achromatic telescopic, mirror, high pass and low pass filters, and EMCCD camera. The FRI images were acquired by a CCD camera using band pass filter centered at 600 nm and high pass max at 615 nm for the first region and high pass filter max at 810 nm for the second region. The SVD and Jacobi SVD algorithms were written in Matlab environment and compared with a Non-negative Matrix Factorization (NMF) and applied to the obtained images. Results PSNR, SNR, CNR of SVD, and NMF methods were obtained as 39 dB, 30.1 dB, and 0.7 dB, respectively. The results showed that the difference of Jacobi SVD PSNR with PSNR of NMF and modified NMF algorithm was significant (p<0.0001). The statistical results showed that the Jacobi SVD was more accurate than modified NMF. Conclusion In this study, the Jacobi SVD was introduced as a powerful method for obtaining the unmixed FRI images. An experimental evaluation of the algorithm will be done in the near future.

کلمات کلیدی:
Fluorescent Reflectance Imaging, Jacobi SVD, Non-Negative Matrix Factorization, Multispectral Imaging, SVD

صفحه اختصاصی مقاله و دریافت فایل کامل: https://civilica.com/doc/942332/