Size specific dose estimate (SSDE) for estimating patient dose from CT used in myocardial perfusion SPECT/CT

سال انتشار: 1399
نوع سند: مقاله ژورنالی
زبان: انگلیسی
مشاهده: 238

فایل این مقاله در 6 صفحه با فرمت PDF قابل دریافت می باشد

استخراج به نرم افزارهای پژوهشی:

لینک ثابت به این مقاله:

شناسه ملی سند علمی:

JR_JNMB-8-1_008

تاریخ نمایه سازی: 24 تیر 1399

چکیده مقاله:

Objective(s): Size specific dose estimate (SSDE) is a new parameter that includes patient size factor in its calculation. Recent studies have produced mixed results on the utility of SSDE, especially when automatic exposure control (AEC) was used. The objective of the study was to find out if there is a relationship between patient size and each of the parameters, SSDE and CTDIvol, when AEC is used. Methods: CT data of consecutively selected 111 patients were included for analysis. CTDIvol values of the CT scans were extracted for each patient. Effective diameter of each patient was calculated as geometric mean of anteroposterior and lateral diameters measured on axial CT images. Corresponding conversion factors for effective diameters were obtained from American Association of Physicists in Medicine (AAPM) report 204. SSDE was obtained as the product of CTDIvol and conversion factor values. Linear regression model was used to evaluate the relationship between patient size and the parameters SSDE and CTDIvol. Results: Mean weight was 62 (11.5) and range was 34 - 103 kg. Median CTDIvol (mGy) on AEC mode was 7.27(IQ range 7.27, 7.65) and mean effective diameter was 26.2 cm (2.4). Mean SSDE (mGy) was 10.6 (0.84). Good positive correlation was obtained between CTDIvol and effective diameter (r=0.536; p<0.0005). Strong inverse correlation was noted between SSDE and effective diameter (r=-0.777; p<0.0005). Linear regression model for establishing relationship between CTDIvol and effective diameter showed slope of 0.314mGy/cm (R=0.561; R2=0.314; P<0.0005) whereas between effective diameter and SSDE slope was -0.23mGy/cm (R=0.676; R2=0.457; P< 0.0005). Conclusion: The study shows that CTDIvol and SSDE vary but divergently, with patient size. SSDE is a better estimate of patient radiation dose from CT of MPI SPECT/CT than CTDIvol in systems that use automated exposure control.

کلیدواژه ها:

SSDE ، CTDI ، Patient dose in CT

نویسندگان

Vishnukumar Rajaraman

Department of Nuclear Medicine, Jawaharlal Institute of Postgraduate Medical Education and Research, Puducherry, India

Madhusudhanan Ponnusamy

Department of Nuclear Medicine, Jawaharlal Institute of Postgraduate Medical Education and Research, Puducherry, India

Dhanapathi Halanaik

Department of Nuclear Medicine, Jawaharlal Institute of Postgraduate Medical Education and Research, Puducherry, India

مراجع و منابع این مقاله:

لیست زیر مراجع و منابع استفاده شده در این مقاله را نمایش می دهد. این مراجع به صورت کاملا ماشینی و بر اساس هوش مصنوعی استخراج شده اند و لذا ممکن است دارای اشکالاتی باشند که به مرور زمان دقت استخراج این محتوا افزایش می یابد. مراجعی که مقالات مربوط به آنها در سیویلیکا نمایه شده و پیدا شده اند، به خود مقاله لینک شده اند :
  • CDC. ALARA - As Low as Reasonably Achievable [Internet]. Centers ...
  • Bauhs JA, Vrieze TJ, Primak AN, Bruesewitz MR, McCollough CH. ...
  • Schindera ST, Nelson RC, Toth TL, Nguyen GT, Toncheva GI, ...
  • Miyazaki O, Horiuchi T, Masaki H, Nosaka S, Miyasaka M, ...
  • McCollough CH, Leng S, Yu L, Cody DD, Boone JM, ...
  • AAPM Reports - Size-Specific Dose Estimates (SSDE) in Pediatric and ...
  • Brady SL, Kaufman RA. Investigation of American Association of Physicists ...
  • Bhatt S, Srivastava AK, Meena N, Thakur S. Appraisal of ...
  • Christner JA, Braun NN, Jacobsen MC, Carter RE, Kofler JM, ...
  • Tsujiguchi T, Obara H, Ono S, Saito Y, Kashiwakura I. ...
  • Strauss KJ. Dose indices: everybody wants a number. Pediatr Radiol. ...
  • Nickoloff EL, Dutta AK, Lu ZF. Influence of phantom diameter, ...
  • Abdollahi H, Shiri I, Salimi Y, Sarebani M, Mehdinia R, ...
  • نمایش کامل مراجع