Design and Construction of an Affordable Phantom for Electron Density Measurement and Linearity Tests of Computed Tomography Systems
محل انتشار: مجله فیزیک پزشکی ایران، دوره: 17، شماره: 1
سال انتشار: 1399
نوع سند: مقاله ژورنالی
زبان: انگلیسی
مشاهده: 272
فایل این مقاله در 10 صفحه با فرمت PDF قابل دریافت می باشد
- صدور گواهی نمایه سازی
- من نویسنده این مقاله هستم
استخراج به نرم افزارهای پژوهشی:
شناسه ملی سند علمی:
JR_IJMP-17-1_007
تاریخ نمایه سازی: 1 مرداد 1399
چکیده مقاله:
Introduction: The performance of computed tomography is routinely checked using phantoms, which are known as important diagnostic imaging tools. Depending upon the aim of the study, different phantoms are designed, while trying to satisfy certain levels of diversities in their application.
Material and Methods: The present study describes the construction of an inexpensive phantom designed for simultaneous measurements of 12 different samples. The body of the phantom, test tube holders, and test tubes were made of materials of low attenuation coefficient. Body of the phantom was filled with water. Test tubes filled with solutions of known chemical compositions were mounted on the test tube holders. The whole phantom was scanned at 80, 100, 120, 140 kVp to evaluate the performance of the CT system. Using Hounsfield Unit (HU) data from these liquid samples of known electron density, the phantom was calibrated for electron density measurements.
Results: The system s accuracy and reproducibility were verified by measuring the HU values for some known materials. According to the results obtained from the experimental datawith liquid samples, the accuracy of the water and noise was within ±3.2 HU and 0.6%, respectively. Moreover, the image uniformity error was less than ±2 HU, and CT system s linearity for calibration was estimated with 99.9% confidence.
Conclusion: The present system gives satisfactory results with known samples and can be used with confidence for characterizing unknown materials.
کلیدواژه ها:
نویسندگان
Rezvan Ravanfar Haghighi
Medical Imaging Research Center, Shiraz University of Medical Sciences, Shiraz, Iran
Sabysachi Chatterjee
Ongil, ۷۹ D۳, Sivaya Nagar, Reddiyur Alagapuram, Salem ۶۳۶۰۰۴. India
Sepideh Sefidbakht
Medical imaging Research Centre, Shiraz University of Medical Sciences, Research Tower, Khalili Street, Shiraz ۷۱۹۳۶۳۵۸۹۹, Iran
Reza Jalli
Medical imaging Research Centre, Shiraz University of Medical Sciences, Research Tower, Khalili Street, Shiraz ۷۱۹۳۶۳۵۸۹۹, Iran