چکیده مقاله:
Introduction: Photoelectric effect and X-ray scattering determine the attenuation coefficient of materials in diagnostic radiology. This manuscript presents an iterative gradient search method to separate the contributions to attenuation from these two independent sources. This issue assumes importance due to two reasons, including 1) Electron density determination of scanned materials and 2) correct dose calculation in diagnostic radiology. Material and Methods: A special water-filled phantom which was custom-built for simultaneous scanning of 12 samples was used in the current study. Attenuation coefficient equations were iteratively solved to calculate the contributions from x-ray scattering and photoelectric effects. Results: Data converged after five iterations (within 1%). Error in the attenuation coefficient was measured at ±3%. Conclusion: As evidenced by the obtained results, this method can be used to determine the Compton and photoelectric contributions with sufficient accuracy. Moreover, the inversion of Dual- Energy computed tomography (DECT) data for finding electron density and effective atomic number of materials also presents satisfactory results.
کلیدواژه ها:
نویسندگان
Fariba Zarei
Medical imaging research center, Shiraz university of medical sciences, Shiraz, Iran
Sabyasachi chatterjee
Ongil, ۷۹ D۳, Sivaya Nagar, Reddiyur Alagapuram, Salem ۶۳۶۰۰۴. India, Retired from Indian Institute of Astrophysics, Bangalore, India
Vani Vardhan Chatterjee
Department of Instrumentation and Applied Physics, Indian Institute of Science, Bangalore ۵۶۰۰۱۲. INDIA
Alireza Shakibafard
Medical imaging Research Centre, Shiraz University of Medical Sciences, Shiraz ۷۱۹۳۶۳۵۸۹۹, Iran
Rezvan Ravanfar Haghighi
Medical Imaging Research Center, Shiraz University of Medical Sciences, Shiraz, Iran
مراجع و منابع این مقاله:
لیست زیر مراجع و منابع استفاده شده در این مقاله را نمایش می دهد. این مراجع به صورت کاملا ماشینی و بر اساس هوش مصنوعی استخراج شده اند و لذا ممکن است دارای اشکالاتی باشند که به مرور زمان دقت استخراج این محتوا افزایش می یابد. مراجعی که مقالات مربوط به آنها در سیویلیکا نمایه شده و پیدا شده اند، به خود مقاله لینک شده اند :