Dosimetric evaluation of IMRT Step and Shoot/ Sliding and Window (SS / SW) and VMAT Treatment Plans for Nasopharyngeal Cancer
محل انتشار: مجله فیزیک پزشکی ایران، دوره: 19، شماره: 1
سال انتشار: 1401
نوع سند: مقاله ژورنالی
زبان: انگلیسی
مشاهده: 149
فایل این مقاله در 12 صفحه با فرمت PDF قابل دریافت می باشد
- صدور گواهی نمایه سازی
- من نویسنده این مقاله هستم
این مقاله در بخشهای موضوعی زیر دسته بندی شده است:
استخراج به نرم افزارهای پژوهشی:
شناسه ملی سند علمی:
JR_IJMP-19-1_005
تاریخ نمایه سازی: 22 اسفند 1400
چکیده مقاله:
Introduction: Radiotherapy of Oto-Rhino-Laryngology (ORL) sphere is difficult due to complex geometries and very sensitive organs around the target volume. This weapon has benefited from the advances of the Volumetric Modulated Arc Therapy (VMAT) technique that combines the advantages of dynamic arc therapy techniques with those of Conformal Radiotherapy with Intensity Modulated (CRIM) by stationary beams.Material and Methods: The treatment plans of ۱۰ patients were compared and treated with Intensity Modulated Radiation Therapy (IMRT) Step and Shoot (SS), Sliding window (SW), and VMAT (۶MV X-ray beam). Three target volumes were used: PTVث Gy, PTV ۶۳ Gy, and PTV ۵۶ Gy. The organs at risk were the spinal cord, the brainstem, the parotid gland. The dose was delivered once a day, five days a week and in ۳۵ sessions in Simultaneous Integrated Boost (SIB).Results: The SS technique permitted better parotid sparing, inducting thus to limiting late complications such as xerostomia. The VMAT technique led to better protection of the brainstem by reducing about ۶ Gy while for the spinal cord the doses received were almost equal. There was no statistically significant difference between the different techniques.Conclusion: The results confirm the conformational capacities of these innovative techniques, from a dosimetric and above all clinical point of view as well as their ability to cover the target volumes while largely respecting the constraints on organs at risk.
کلیدواژه ها:
نویسندگان
Rachid Errifai
Department of Physics, LPHE, Modeling and Simulations, Faculty of Science, Mohammed V University, Rabat, Morocco
Youssef Bouzekraoui
Hassan First University of Settat, High Institute of Health Sciences, Laboratory of Sciences and Health Technologies, Settat, Morocco
FARIDA BENTAYEB
Department of Physics, LPHE, Modeling and Simulations, Faculty of Science, Mohammed V University, Rabat, Morocco
مراجع و منابع این مقاله:
لیست زیر مراجع و منابع استفاده شده در این مقاله را نمایش می دهد. این مراجع به صورت کاملا ماشینی و بر اساس هوش مصنوعی استخراج شده اند و لذا ممکن است دارای اشکالاتی باشند که به مرور زمان دقت استخراج این محتوا افزایش می یابد. مراجعی که مقالات مربوط به آنها در سیویلیکا نمایه شده و پیدا شده اند، به خود مقاله لینک شده اند :