Efficiency improvement and inrush current reduction in a non-isolated DC-DC converter
سال انتشار: 1398
نوع سند: مقاله ژورنالی
زبان: انگلیسی
مشاهده: 133
فایل این مقاله در 8 صفحه با فرمت PDF قابل دریافت می باشد
- صدور گواهی نمایه سازی
- من نویسنده این مقاله هستم
استخراج به نرم افزارهای پژوهشی:
شناسه ملی سند علمی:
JR_IECO-2-2_006
تاریخ نمایه سازی: 20 تیر 1401
چکیده مقاله:
DC–DC boost converters are unable to provide high step-up voltage gains due to the effect of power switches, rectifier diodes, and the equivalent series resistance of inductors and capacitors. A high step-up DC-DC converter based on the modified SEPIC converter is presented in this paper. Step up non-isolated converters generally suffer from problems such as high voltage stress and low efficiency. In this study, non-isolated boost converter structures, SEPIC, SEPIC modified circuit, and a proposed converter is studied. Then compare the performance of these typologies is located and presented as a chart. The operation analysis, design procedure for proposed converter is obtaied from ۱۵V input voltage and ۱۵۰V output voltage and with ۱۰۰ watts output power. Using the proposed converter, the input inrush current and the invading voltage of the output have decreased. The time response analysis states that the proposed converter acts faster with deployment time than other converters.
کلیدواژه ها:
نویسندگان
Saeid Moosavi
Engineering Department, Amol University of Special Modern technologies, Amol, IRAN