مطالعه ی آزمایشگاهی تاثیر نصب اسپویلر و پیگیبک لاین در لوله های موازی مستغرق قرارگرفته در بستر فرسایشی تحت جریان یک طرفه

سال انتشار: 1401
نوع سند: مقاله ژورنالی
زبان: فارسی
مشاهده: 113

نسخه کامل این مقاله ارائه نشده است و در دسترس نمی باشد

استخراج به نرم افزارهای پژوهشی:

لینک ثابت به این مقاله:

شناسه ملی سند علمی:

JR_SJCE-38-1_001

تاریخ نمایه سازی: 16 مهر 1401

چکیده مقاله:

The bed formations of submarine pipelines models were measured to investigate the effect of design parameters such as the distance between two submarine pipelines and also the effect of adjusted rectangular spoiler due to different angles of adjustment. To investigate the hydraulic parameters, three experimental models of parallel pipelines with three distances were made through the hydraulic laboratory. By considering the threshold velocity, the bed profiles were measured experimentally by employing the point gauge apparatus due to changing the angle of considered spoilers. Results indicate that increasing the distance between two submarine pipelines is the reason why that the downstream scour hole was formed independently from the upstream scour hole, which was developed under the upstream pipelines. Also, due to different angles of spoilers, the scour hole of spoiler with angle ۹۰o formed the same as the witness model (with no spoiler), showing that angle ۹۰o has no marginal effect on scour hole formation process. However, the angle of ۱۸۰o adjusted on two submarine pipelines made the maximum scour hole under the upstream and downstream pipelines. It is assumed that the spoiler ۱۸۰o affects the downstream flow of the pipelines and by creating the region with low pressure behind the pipelines, the scour holes were plunged to the bed and the depth of the scour holes increased significantly. Also, the investigation of spoiler position on the two pipe lines illustrates that by adjusting the spoiler on the downstream pipelines, the downstream pipe was buried under the sediment. These conditions were observed by angles of ۱۳۵o, ۱۸۰o, and ۲۲۵o. It is assumed that increasing the distance between two submarine pipelines diminishes the rate of self-burial conditions. It appears that by increasing the distance between two pipelines, the effect of the upstream pipeline was omitted because the downstream and upstream pipelines were scoured as two single pipes; thus, the upstream pipelines did not affect the downstream pipelines.

نویسندگان

مجتبی دامرودی

دانشکده ی فنی و مهندسی عمران، دانشگاه آزاد اسلامی، واحد نجف آباد، اصفهان

کاظم اسماعیلی

گروه علوم و مهندسی آب ، دانشگاه فردوسی مشهد

سیدحسن رجایی

مرکز تحقیقات و آموزش کشاورزی و منابع طبیعی، مشهد، استان خراسان رضوی