A New Software for Patient Dose Extraction and Assessment from CT DICOM Images
محل انتشار: مجله فیزیک پزشکی ایران، دوره: 20، شماره: 3
سال انتشار: 1402
نوع سند: مقاله ژورنالی
زبان: انگلیسی
مشاهده: 68
فایل این مقاله در 6 صفحه با فرمت PDF قابل دریافت می باشد
- صدور گواهی نمایه سازی
- من نویسنده این مقاله هستم
استخراج به نرم افزارهای پژوهشی:
شناسه ملی سند علمی:
JR_IJMP-20-3_002
تاریخ نمایه سازی: 30 خرداد 1402
چکیده مقاله:
Introduction: Radiation dose monitoring is an important objective of radiation safety and quality assurance program. The purpose of this study was to develop an automated approach for monitoring and estimating patient radiation doses from Computed Tomography (CT) examinations, Automated software, based on MATrix LABoratory (MATLAB) environment, was introduced for extracting and analyzing patient dose identifiers from Digital Imaging and Communications in Medicine (DICOM) CT image files. In addition, an estimation of effective dose and statistical studies were implemented.Material and Methods: A random sample of ۱۴۶۶ patients’ CT DICOM image files were collected from a ۶۴-slice Siemens’ Somatom Perspective CT scanner. The proposed Graphical User Interface (GUI) extracts the volumetric CT dose index (CTDIvol), the dose length product (DLP) for each phase of scan session in order to calculate the patient radiation effective dose (E). A graphical layout presenting statistical values was were also produced, e according to study date, patient sex, and CT protocol type.Results: The GUI performance was verified according to the manually proceeded results. The extraction speed and accuracy of the radiation dose values were satisfactory, as compared to the approaches presented in literatures such as optical character recognition (OCR) technology, and the direct extraction from the metadata of CT image files.Conclusion: The proposed GUI performs the extraction of CT patient dose metrics CTDIvol, DLP with a satisfactory speed and accuracy. The obtained results could be shown in numerical and graphical formats, and it could be used for radiation dose monitoring and Diagnostic Reference Levels (DRLs) establishing purposes with multiple filtering capacities.
کلیدواژه ها:
نویسندگان
Tabarak Darkal
Department of Physics, Faculty of Science, University of Damascus, Syria
Yehia LAHFI
Protection and Safety Department, Atomic Energy Commission of SYRIA, Damascus, Syria
Ali Al-Khatib
Department of Physics, Faculty of Science, University of Damascus, Syria
مراجع و منابع این مقاله:
لیست زیر مراجع و منابع استفاده شده در این مقاله را نمایش می دهد. این مراجع به صورت کاملا ماشینی و بر اساس هوش مصنوعی استخراج شده اند و لذا ممکن است دارای اشکالاتی باشند که به مرور زمان دقت استخراج این محتوا افزایش می یابد. مراجعی که مقالات مربوط به آنها در سیویلیکا نمایه شده و پیدا شده اند، به خود مقاله لینک شده اند :