Patient-Specific Radiation Dose and Cancer Risk in Computed Tomography Examinations in Ondo, Nigeria
محل انتشار: مجله فیزیک پزشکی ایران، دوره: 16، شماره: 1
سال انتشار: 1398
نوع سند: مقاله ژورنالی
زبان: انگلیسی
مشاهده: 79
فایل این مقاله در 6 صفحه با فرمت PDF قابل دریافت می باشد
- صدور گواهی نمایه سازی
- من نویسنده این مقاله هستم
استخراج به نرم افزارهای پژوهشی:
شناسه ملی سند علمی:
JR_IJMP-16-1_012
تاریخ نمایه سازی: 5 شهریور 1402
چکیده مقاله:
Introduction: The dose in computed tomography (CT) often approach or exceed the optimum levels, thereby increasing the probability of cancer induction. With wide application of this diagnostic test, it is expedient to determine the effective dose (ED) for each patient to estimate their cancer risk. This study was conducted to investigate the patient-specific dose (PSD) and cancer risk in CT examinations in Ondo, Nigeria. Material and Methods: The study was conducted on ۱۶۰ patients undergoing eight most common types of CT examinations performed at the center, from December ۵, ۲۰۱۵ to February ۲۸, ۲۰۱۶. Body mass index (BMI) was calculated for each patient using demographic data, PSD was determined and estimation of the lifetime attributable risk (LAR) of cancer was accomplished using the Biologic Effects of Ionizing Radiation VII (۲۰۰۶) report phase ۲ models. Results: From the results, radiation doses varied significantly within and between the types of CT examinations. The mean ED was ۵.۸۸±۳.۷۵ mSv in a range of ۰.۷۸-۱۹.۰۰ mSv. The mean PSD was ۰.۲۷۴±۰.۲۲۹ mSv/kgm-۲ in a range of ۰.۰۲۴-۱.۵۵۵ mSv/kgm-۲ and the mean LAR of cancer incidence was ۰.۰۴۸۶۱±۰.۰۳۹۹۶ Sv-۱ in a range of ۰.۰۰۰۰۴-۰.۲۱۹۴۲ Sv-۱. Conclusion: ED and PSD varied within and across the CT examinations. In this regard, the coefficients of variation of ED for abdominal, cranial, craniocervical, abdomen/pelvis, thoracic, thoracoabdominal, cervical spine, and pelvis were ۵.۷%, ۶.۶%, ۳.۹%, ۸.۹%,۳.۷%, ۶.۰%, ۴۴.۷%, and ۱۹.۲%, respectively. Accordingly, the coefficients of variation of PSD were ۹.۰%, ۷.۹%, ۷.۰%, ۱۰.۱%,۵.۶%,۲۳.۸%, ۴۷.۷%, and ۱۴.۲%.
کلیدواژه ها:
نویسندگان
Tajudeen Olaniyan
Department of Physics, Faculty of Science, Obafemi Awolowo University, Ile-Ife, Nigeria
Caleb Aborisade
Department of Physics, Faculty of Science, Obafemi Awolowo University, Ile-Ife, Nigeria
Fatai Balogun
Centre for Energy Research and Development, OAU, Ile-Ife. Nigeria
Sulaiman Ogunsina
Department of Physics, Faculty of Science, Obafemi Awolowo University, Ile-Ife, Nigeria
Aminu Saidu
Department of Physics, Faculty of Science, Usmanu Danfodiyo University, Sokoto Nigeria
Mark Ibrahim
Department of Physics, Faculty of Science, Obafemi Awolowo University, Ile-Ife, Nigeria
مراجع و منابع این مقاله:
لیست زیر مراجع و منابع استفاده شده در این مقاله را نمایش می دهد. این مراجع به صورت کاملا ماشینی و بر اساس هوش مصنوعی استخراج شده اند و لذا ممکن است دارای اشکالاتی باشند که به مرور زمان دقت استخراج این محتوا افزایش می یابد. مراجعی که مقالات مربوط به آنها در سیویلیکا نمایه شده و پیدا شده اند، به خود مقاله لینک شده اند :