Compensation of Cross-Contamination in Simultaneous ۲۰۱Tl/۹۹mTc Myocardial Perfusion SPECT Imaging

سال انتشار: 1388
نوع سند: مقاله ژورنالی
زبان: انگلیسی
مشاهده: 56

فایل این مقاله در 14 صفحه با فرمت PDF قابل دریافت می باشد

استخراج به نرم افزارهای پژوهشی:

لینک ثابت به این مقاله:

شناسه ملی سند علمی:

JR_IJMP-6-0_007

تاریخ نمایه سازی: 5 شهریور 1402

چکیده مقاله:

Introduction: It is a common protocol to use ۲۰۱Tl for the rest and ۹۹mTc for the stress cardiac SPECT imaging. Theoretically, both types of imaging may be performed simultaneously using different energy windows for each radionuclide. However, a potential limitation is the cross-contamination of scattered photons from ۹۹mTc and collimator X-rays into the ۲۰۱Tl energy window. We used a middle energy window method to correct this cross-contamination. Material and Methods: Using NCAT, a typical software torso phantom was generated. An extremely thin line source of ۹۹mTc activity was placed inside the cardiac region of the phantom and no activity in the other parts.  The SimSET Monte Carlo simulator was used to image the phantom in different energy windows. To find the relationship between projections in different energy windows, deconvolution theory was used. We investigated the ability of the suggested functions in three steps: Monte Carlo simulation, phantom experiment and clinical study. In the last step, SPECT images of eleven patients who had angiographic data were acquired in different energy windows. All of these images were compared by determining the contrast between a defect or left ventricle cavity and the myocardium. Results: We found a new ۲D kernel which had an exponential pattern with a much higher center. This function was used for modeling ۹۹mTc down scatter distribution from the middle window image. X-ray distribution in the ۲۰۱Tl window was also modeled as the ۹۹mTc photopeak image convolved by a Gaussian function. Significant improvements in the contrasts of the simultaneous dual ۲۰۱Tl images were found in each step before and after reconstruction. In comparison with other similar methods, better results were acquired using our suggested functions. Conclusion: Our results showed contrast improvement in thallium images after correction, however, many other parameters should be evaluated for clinical approaches. There are many advantages in simultaneous dual isotope imaging. It halves imaging time and reduces patient waiting time and discomfort. Identical rest/stress registration of images also facilitates physicists’ motion or attenuation corrections and physicians’ image interpretation.

نویسندگان

Faraz Kalantari

PhD Student, Medical Physics Dept., Faculty of Medical Sciences, Tarbiat Modares University, Tehran, Iran

Hossein Rajabi

Associate Professor, Medical Physics Dept., Faculty of Medical Sciences, Tarbiat Modares University, Tehran, Iran

Nahid Yaghoobi

Assistant Professor, Nuclear Medicine Dept., Rajaei Heart Center, Iran University of Medical Sciences, Tehran, Iran

Ahmad Bitarafan

Assistant Professor, Nuclear Medicine Dept., Rajaei Heart Center, Iran University of Medical Sciences, Tehran, Iran