Comparative Study of OpenFOAM Solvers on Separation Pattern and Separation Pattern Transition in Overexpanded Single Expansion Ramp Nozzle

سال انتشار: 1402
نوع سند: مقاله ژورنالی
زبان: انگلیسی
مشاهده: 95

فایل این مقاله در 14 صفحه با فرمت PDF قابل دریافت می باشد

استخراج به نرم افزارهای پژوهشی:

لینک ثابت به این مقاله:

شناسه ملی سند علمی:

JR_JAFM-16-11_012

تاریخ نمایه سازی: 22 شهریور 1402

چکیده مقاله:

Flow separation in overexpanded single expansion ramp nozzles (SERN) involves complex phenomena, such as shock waves, expansion waves, turbulent boundary layers, and shear layers. Computational fluid dynamics plays a crucial role in studying unsteady flow behaviour in supersonic nozzles, allowing for an investigation into the dynamic flow field characteristics. However, the application of OpenFOAM as a numerical tool for studying SERN in the field of compressible flows, particularly in the overexpansion state where the flow field characteristics are more complex, has received relatively less attention. In this study, the flow field characteristics of an overexpanded SERN under different turbulence models are investigated through a combination of experiments and numerical calculations. The qualitative and quantitative predictive performance of two compressible flow solvers in OpenFOAM, namely, rhoCentralFOAM and sonicFOAM, are compared in terms of flow separation pattern and separation pattern transitions within the overexpanded SERN. The ability of rhoCentralFOAM and sonicFOAM to accurately predict complex flow states is evaluated. Results indicate that the numerical simulations conducted using rhoCentralFOAM and sonicFOAM successfully capture flow separation, separated shock waves, separated bubbles and shear layers for two types of restricted shock separation patterns at the same nozzle pressure ratio (NPR), demonstrating agreement with experimental results. However, sonicFOAM initiates the transition in the separation pattern ۰.۰۷۷۳ NPR earlier than rhoCentralFOAM during the whole separation pattern transition process of the SERN. The transition process in sonicFOAM lasts longer and exhibits a greater variation in NPR. SonicFOAM fails to accurately predict certain aspects, such as the pressure rise after the separation bubble, the reattachment shock wave, and tends to overestimat the length of the separation shock length. Consequently, sonicFOAM cannot be recommended as a suitable solver for accurately capturing the separation pattern of an overexpanded nozzle.

کلیدواژه ها:

نویسندگان

T. Yu

School of Aeronautics, Chongqing Jiaotong University, ۴۰۰۰۷۴, Chongqing, China

Y. Yu

School of Aeronautics, Chongqing Jiaotong University, ۴۰۰۰۷۴, Chongqing, China

Y. P. Mao

The Green Aerotechnics Research Institute of Chongqing Jiaotong University, Chongqing Key Laboratory of Green Aviation energy and power, ۴۰۱۱۲۰, Chongqing, China

Y. L. Yang

School of Aeronautics, Chongqing Jiaotong University, ۴۰۰۰۷۴, Chongqing, China

S. L. Xu

The Green Aerotechnics Research Institute of Chongqing Jiaotong University, Chongqing Key Laboratory of Green Aviation energy and power, ۴۰۱۱۲۰, Chongqing, China

مراجع و منابع این مقاله:

لیست زیر مراجع و منابع استفاده شده در این مقاله را نمایش می دهد. این مراجع به صورت کاملا ماشینی و بر اساس هوش مصنوعی استخراج شده اند و لذا ممکن است دارای اشکالاتی باشند که به مرور زمان دقت استخراج این محتوا افزایش می یابد. مراجعی که مقالات مربوط به آنها در سیویلیکا نمایه شده و پیدا شده اند، به خود مقاله لینک شده اند :