Simulation of the Natural Gas Pipeline Explosion by Using PHAST Software and Investigation of Line Break Valve’s Effectiveness
محل انتشار: مجله تکنولوژی گاز، دوره: 7، شماره: 1
سال انتشار: 1401
نوع سند: مقاله ژورنالی
زبان: انگلیسی
مشاهده: 105
فایل این مقاله در 17 صفحه با فرمت PDF قابل دریافت می باشد
- صدور گواهی نمایه سازی
- من نویسنده این مقاله هستم
استخراج به نرم افزارهای پژوهشی:
شناسه ملی سند علمی:
JR_JGT-7-1_006
تاریخ نمایه سازی: 29 آبان 1402
چکیده مقاله:
Two points need to be taken into consideration regarding buildings built around gas transmission pipelines in Iran, first, the density of the buildings and second, the distance from the axis of the pipeline. These values are determined by standard tables IGS-C-SF-۰۱۵. Nevertheless, determining the two mentioned factors is not enough to determine the risk level of threats caused by gas pipelines explosion. The best way to calculate the risk level that threatens buildings around pipelines is by using computer calculations such as PHAST software to estimate the consequences of accidents and analyze the results based on natural accidents. However, it is worth mentioning that the PHAST software also cannot calculate the effects of soil in the explosion of burial pipes. Hence, the simulation by PHAST for an explosion-exposed gas pipeline can be a basis for other evaluations. After determining the appropriate consequence modelling, the effectiveness of using equipment that can reduce the explosion‘s consequences is also investigated. In this paper, after logical modelling for the real explosion, the effectiveness of a standard protective device in gas pipelines called Line Break Valve (LBV) for reducing the explosion’s consequences is measured. At first, the probability of the LBV functioning at the time of the explosion is checked. Subsequently, by the diagram, the consequences of the accident for two modes of operation and non-operation of the LBV system are displayed and compared with each other. Ultimately, for the simulated mode, it is observed that the correct operation of the LBV system could reduce the accident consequences by more than ۶۰%.
کلیدواژه ها:
نویسندگان
Meisam Doust mohammadi
PhD Candidate، Department of Civil Engineering،Arak Branch, Islamic Azad University،Arak,، Iran.
SeyedMohammad Mirhosseini
Assistant Professor, Department of Civil Engineering, Arak Branch, Islamic Azad University, Arak, Iran
Seye Hamid Lajevardi
Assistant Professor, Department of Civil Engineering, Arak Branch, Islamic Azad University, Arak, Iran
Ehsanollah Zeighami
Assistant Professor, Department of Civil Engineering, Arak Branch, Islamic Azad University, Arak, Iran
مراجع و منابع این مقاله:
لیست زیر مراجع و منابع استفاده شده در این مقاله را نمایش می دهد. این مراجع به صورت کاملا ماشینی و بر اساس هوش مصنوعی استخراج شده اند و لذا ممکن است دارای اشکالاتی باشند که به مرور زمان دقت استخراج این محتوا افزایش می یابد. مراجعی که مقالات مربوط به آنها در سیویلیکا نمایه شده و پیدا شده اند، به خود مقاله لینک شده اند :