Identifying Affecting Factors on Acceptance with CPAP on the First Night of PAP Titration in Sleep Clinic on Patients with Obstructive Sleep Apnea
سال انتشار: 1402
نوع سند: مقاله ژورنالی
زبان: انگلیسی
مشاهده: 46
فایل این مقاله در 7 صفحه با فرمت PDF قابل دریافت می باشد
- صدور گواهی نمایه سازی
- من نویسنده این مقاله هستم
استخراج به نرم افزارهای پژوهشی:
شناسه ملی سند علمی:
JR_IJOTO-35-6_002
تاریخ نمایه سازی: 4 آذر 1402
چکیده مقاله:
Introduction:This research examined the causes of low acceptance with Continuous Positive Airway Pressure Continuous Positive Airway Pressure (CPAP) especially anatomical causes and if eliminating them would result in increasing its adherence. Materials and Methods:This cross sectional study was performed on patients with moderate to severe Obstructive Sleep Apnea Obstructive Sleep Apnea (OSA) undergoing PAP titration in the sleep clinic. CPAP acceptance was evaluated by visual analog scale (VAS) about mask and sleep satisfaction and the possibility of using CPAP in the future, mask complications, physical examination of the upper airway and polysomnographic (PSG) results before and after titration. Results:participants were divided into three groups of non-acceptant, semi-acceptant and acceptant with CPAP based on the satisfaction of the mask and sleep. There were no significant differences between groups based on age, gender, education, BMI and polysomnographic variables. With a study of mask complication, there were significant differences among groups for dry mouth, mask leakage and cold air. (p<۰.۰۵) The severity of septal deviation, high arch palate, mallampati, retrognathia and maxillary hypoplasia in the acceptant group was less than the other two groups, but it was not statistically significant. Conclusions:Satisfaction with the sleep and the mask on the first night of titration will significantly increase the likelihood of using CPAP in the future. A number of the pathological physical examinations were lower in the acceptant group than two other groups, but were not significant.
کلیدواژه ها:
نویسندگان
Reihaneh Heidari
Otorhinolaryngology Research Center, Imam Khomeini Hospital Complex, Tehran University of Medical Sciences, Tehran, Iran.
Ayeh Shamsadini
Otorhinolaryngology Research Center, Imam Khomeini Hospital Complex, Tehran University of Medical Sciences, Tehran, Iran.
Arezu Najafi
Occupational Sleep Research Center, Baharloo Hospital, Tehran University of Medical Sciences, Tehran, Iran.
Reza Erfanian
Otorhinolaryngology Research Center, Tehran University of Medical Sciences, Tehran, Iran.
مراجع و منابع این مقاله:
لیست زیر مراجع و منابع استفاده شده در این مقاله را نمایش می دهد. این مراجع به صورت کاملا ماشینی و بر اساس هوش مصنوعی استخراج شده اند و لذا ممکن است دارای اشکالاتی باشند که به مرور زمان دقت استخراج این محتوا افزایش می یابد. مراجعی که مقالات مربوط به آنها در سیویلیکا نمایه شده و پیدا شده اند، به خود مقاله لینک شده اند :