A System for Continuous Estimating and Monitoring Cardiac Output via Arterial Waveform Analysis

سال انتشار: 1396
نوع سند: مقاله ژورنالی
زبان: انگلیسی
مشاهده: 73

فایل این مقاله در 10 صفحه با فرمت PDF قابل دریافت می باشد

استخراج به نرم افزارهای پژوهشی:

لینک ثابت به این مقاله:

شناسه ملی سند علمی:

JR_JBPE-7-2_011

تاریخ نمایه سازی: 30 دی 1402

چکیده مقاله:

Background: Cardiac output (CO) is the total volume of blood pumped by the heart per minute and is a function of heart rate and stroke volume. CO is one of the most important parameters for monitoring cardiac function, estimating global oxygen delivery and understanding the causes of high blood pressure. Hence, measuring CO has always been a matter of interest to researchers and clinicians. Several methods have been developed for this purpose, but a majority of them are either invasive, too expensive or need special expertise and experience. Besides, they are not usually risk free and have consequences.Objective: Here, a semi-invasive system was designed and developed for continuous CO measurement via analyzing and processing arterial pulse waves. Results: Quantitative evaluation of developed CO estimation system was performed using ۷ signals. It showed that it has an acceptable average error of (۶.۵%) in estimating CO. In addition, this system has the ability to consistently estimate this parameter and to provide a CO versus time curve that assists in tracking changes of CO. Moreover, the system provides such curve for systolic blood pressure, diastolic blood pressure, average blood pressure, heart rate and stroke volume.Conclusion: Evaluation of the results showed that the developed system is capable of accurately estimating CO. The curves which the system provides for important parameters may be valuable in monitoring hemodynamic status of high-risk surgical patients and critically ill patients in Intensive Care Units (ICU). Therefore, it could be a suitable system for monitoring hemodynamic status of critically ill patients.

نویسندگان

A Vakily

Department of Medical Physics and Engineering, Shiraz University of Medical Sciences, Shiraz, Iran

H Parsaei

Department of Medical Physics and Engineering, Shiraz University of Medical Sciences, Shiraz, Iran

M M Movahhedi

Department of Medical Physics and Engineering, Shiraz University of Medical Sciences, Shiraz, Iran

M A Sahmeddini

Shiraz Anesthesiology and Critical Care Research Center, Shiraz University of Medical Sciences, Shiraz, Iran

مراجع و منابع این مقاله:

لیست زیر مراجع و منابع استفاده شده در این مقاله را نمایش می دهد. این مراجع به صورت کاملا ماشینی و بر اساس هوش مصنوعی استخراج شده اند و لذا ممکن است دارای اشکالاتی باشند که به مرور زمان دقت استخراج این محتوا افزایش می یابد. مراجعی که مقالات مربوط به آنها در سیویلیکا نمایه شده و پیدا شده اند، به خود مقاله لینک شده اند :
  • Ahrens T. Hemodynamics in sepsis. AACN Adv Crit Care. ۲۰۰۶;۱۷:۴۳۵-۴۵. ...
  • Ince C, Sinaasappel M. Microcirculatory oxygenation and shunting in sepsis ...
  • Beal AL, Cerra FB. Multiple organ failure syndrome in the ...
  • Connors AF, Jr., Speroff T, Dawson NV, Thomas C, Harrell ...
  • Meier-Hellmann A, Sakka S, Reinhart K. Supportive therapy of the ...
  • Rivers E. The outcome of patients presenting to the emergency ...
  • Zanotti Cavazzoni SL, Dellinger RP. Hemodynamic optimization of sepsis-induced tissue ...
  • Brumfield AM, Andrew ME. Digital pulse contour analysis: investigating age-dependent ...
  • Garcia X, Mateu L, Maynar J, Mercadal J, Ochagavia A, ...
  • Hall JE. Guyton and Hall textbook of medical physiology. Saunders ...
  • Berne RM, Levy MN. Cardiovascular Physiology. ۷th ed. St. Louis ...
  • Ranganathan N, Sivaciyan V, Saksena FB. The art and science ...
  • J Sun JX. Cardiac output estimation using arterial blood pressure ...
  • Webster J. Medical instrumentation: application and design: John Wiley & ...
  • Marik PE, Varon J. The hemodynamic derangements in sepsis: implications ...
  • Marik PE. Gastric intramucosal pH. A better predictor of multiorgan ...
  • van Heerden PV, Baker S, Lim SI, Weidman C, Bulsara ...
  • Nilsson LB, Eldrup N, Berthelsen PG. Lack of agreement between ...
  • Beaulieu Y, Marik PE. Bedside ultrasonography in the ICU: part ...
  • Beaulieu Y, Marik PE. Bedside ultrasonography in the ICU: part ...
  • Bein B, Worthmann F, Tonner PH, Paris A, Steinfath M, ...
  • Wesseling KH, Jansen JR, Settels JJ, Schreuder JJ. Computation of ...
  • Duvall WL, Croft LB, Goldman ME. Can hand-carried ultrasound devices ...
  • Cheung AT, Savino JS, Weiss SJ, Aukburg SJ, Berlin JA. ...
  • Reichert CL, Visser CA, Koolen JJ, vd Brink RB, van ...
  • Porter RS, Nester BA, Dalsey WC, O’Mara M, Gleeson T, ...
  • Tso P, Rodriguez A, Cooper C, Militello P, Mirvis S, ...
  • De Backer D, Creteur J, Preiser JC, Dubois MJ, Vincent ...
  • Lefrant JY, Bruelle P, Aya AG, Saissi G, Dauzat M, ...
  • Dark PM, Singer M. The validity of trans-esophageal Doppler ultrasonography ...
  • Brumfield AM, Andrew ME. Digital pulse contour analysis: investigating age-dependent ...
  • Raaijmakers E, Faes TJ, Scholten RJ, Goovaerts HG, Heethaar RM. ...
  • Reuter DA, Goetz AE. Measurement of cardiac output. Anaesthesist. ۲۰۰۵;۵۴:۱۱۳۵-۵۱; ...
  • Marik PE, Pendelton JE, Smith R. A comparison of hemodynamic ...
  • Karamanoglu M. A system for analysis of arterial blood pressure ...
  • Saba PS, Roman MJ, Pini R, Spitzer M, Ganau A, ...
  • Garcia X, Mateu L, Maynar J, Mercadal J, Ochagavia A, ...
  • Phillips RA, Hood SG, Jacobson BM, West MJ, Wan L, ...
  • de Wilde RB, Schreuder JJ, van den Berg PC, Jansen ...
  • Su BC, Tsai YF, Chen CY, Yu HP, Yang MW, ...
  • Romano SM, Pistolesi M. Assessment of cardiac output from systemic ...
  • Scolletta S, Romano SM, Biagioli B, Capannini G, Giomarelli P. ...
  • Scolletta S, Gregoric ID, Muzzi L, Radovancevic B, Frazier OH. ...
  • Kazanavicius E, Gircys R, Vrubliauskas A, Lugin S. Mathematical methods ...
  • Singh M, Nagpal S. Features Extraction in Second Derivative of ...
  • Johnson AEW, Pollard TJ, Shen L, Lehman L, Feng M, ...
  • نمایش کامل مراجع