Evaluation of the Effect of Source Geometry on the Output of Miniature X-ray Tube for Electronic Brachytherapy through Simulation

سال انتشار: 1397
نوع سند: مقاله ژورنالی
زبان: انگلیسی
مشاهده: 49

فایل این مقاله در 14 صفحه با فرمت PDF قابل دریافت می باشد

استخراج به نرم افزارهای پژوهشی:

لینک ثابت به این مقاله:

شناسه ملی سند علمی:

JR_JBPE-8-1_004

تاریخ نمایه سازی: 30 دی 1402

چکیده مقاله:

Objective: The use of miniature X-ray source in electronic brachytherapy is on the rise so there is an urgent need to acquire more knowledge on X-ray spectrum production and distribution by a dose. The aim of this research was to investigate the influence of target thickness and geometry at the source of miniature X-ray tube on tube output.Method: Five sources were simulated based on problems each with a specific geometric structure and conditions using MCNPX code. Tallies proportional to the output were used to calculate the results for the influence of source geometry on output.Results: The results of this work include the size of the optimal thickness of ۵ miniature sources, energy spectrum of the sources per ۵۰ kev and also the axial and transverse dose of simulated sources were calculated based on these thicknesses. The miniature source geometric was affected on the output x-ray tube.Conclusion: The result of this study demonstrates that hemispherical-conical, hemispherical and truncated-conical miniature sources were determined as the most suitable tools.

نویسندگان

B Barati

Department of Medical Physics, School of Medicine, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, Iran

M Zabihzadeh

Department of Medical Physics, School of Medicine, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, Iran

M J Tahmasebi Birgani

Department of Medical Physics, School of Medicine, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, Iran

N Chegini

Department of Medical Physics, School of Medicine, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, Iran

J Fatahiasl

Department of Medical Physics, School of Medicine, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, Iran

I Mirr

Department of Biostatistics and Epidemiology, School of Health, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, Iran

مراجع و منابع این مقاله:

لیست زیر مراجع و منابع استفاده شده در این مقاله را نمایش می دهد. این مراجع به صورت کاملا ماشینی و بر اساس هوش مصنوعی استخراج شده اند و لذا ممکن است دارای اشکالاتی باشند که به مرور زمان دقت استخراج این محتوا افزایش می یابد. مراجعی که مقالات مربوط به آنها در سیویلیکا نمایه شده و پیدا شده اند، به خود مقاله لینک شده اند :
  • Cho SO, Heo SH. Super miniature X-ray tube using NANO ...
  • Choe KS, Liauw SL. Radiotherapeutic strategies in the management of ...
  • Porter AT, Blasko JC, Grimm PD, Reddy SM, Ragde H. ...
  • Kubo HD, Glasgow GP, Pethel TD, Thomadsen BR, Williamson JF. ...
  • Gierga DP, Shefer RE. Characterization of a soft X-ray source ...
  • Heoa S, Haa J, Choa S. An Optimization of Super-Miniature ...
  • Dinsmore M, Harte KJ, Sliski AP, Smith DO, Nomikos PM, ...
  • Ihsan A, Heo SH, Kim HJ, Kang CM, Cho SO. ...
  • Rivard MJ, Davis SD, DeWerd LA, Rusch TW, Axelrod S. ...
  • Rivard MJ, Rusch TW, Axelrod S. Radiological dependence of electronic ...
  • Silvern D, Rusch T, Zaider M, editors Dosimetric Benefits of ...
  • Hiatt JR, Davis SD, Rivard MJ. A revised dosimetric characterization ...
  • Rong Y, Welsh JS. New technology in high-dose-rate brachytherapy with ...
  • Liu DMC. Characterization of novel electronic brachytherapy system. Montreal: McGill ...
  • Holt RW, Rivard MJ. Electronic brachytherapy: comparisons with external-beam and ...
  • Clausen S, Schneider F, Jahnke L, Fleckenstein J, Hesser J, ...
  • Grobmyer SR, Lightsey JL, Bryant CM, Shaw C, Yeung A, ...
  • Chiu-Tsao S-T, Davis S, Pike T, DeWerd LA, Rusch TW, ...
  • Kelley L, Axelrod S, Dutta A. SU-DD-A۲-۰۳: Measurement of Skin ...
  • Holt RW, Thomadsen BR, Orton CG. Point/Counterpoint. Miniature x-ray tubes ...
  • Ballester-Sanchez R, Pons-Llanas O, Candela-Juan C, Celada-Alvarez FJ, de Unamuno-Bustos ...
  • Beatty J, Biggs PJ, Gall K, Okunieff P, Pardo FS, ...
  • Eaton DJ, Duck S. Dosimetry measurements with an intra-operative x-ray ...
  • Hendricks JS, McKinney GW, Fensin ML, James MR, Johns RC, ...
  • Ay MR, Shahriari M, Sarkar S, Adib M, Zaidi H. ...
  • McKinney G, Durkee J, Waters L, Pelowitz D, James M, ...
  • Braga MR, Penna R, Vasconcelos DC, Pereira C, Guerra BT, ...
  • Ihsan A, Heo SH, Cho SO. Optimization of X-ray target ...
  • Grant EJ, Posada CM, Castano CH, Lee HK, editors. Electron ...
  • McConn RJ, Gesh CJ, Pagh RT, Rucker RA, Williams III ...
  • Hughes III HG. Summary of DBCN Options in MCNP۶. Los ...
  • Pelowitz D, Durkee J, Elson J, Fensin M, James M, ...
  • Nasseri MM. Determination of tungsten target parameters for transmission X-ray ...
  • Seibert JA. X-ray imaging physics for nuclear medicine technologists. Part ...
  • Mordechai S. Applications of Monte Carlo method in science and ...
  • Ganguly A, Karim R. Essential physics for radiology and imaging. ...
  • Zoubair M, El Bardouni T, Allaoui O, Boulaich Y, El ...
  • Ihsan A, Heo SH, Cho SO. A microfocus X-ray tube ...
  • Sukowski F, Uhlmann N. Monte Carlo Simulations in NDT. Applications ...
  • Wang R, Pei L, Huang Z. Study on Calculation of ...
  • Davis SD. Air-kerma strength determination of a miniature x-ray source ...
  • Malabre-O’Sullivan N. Low energy photon mimic of the tritium beta ...
  • Williams T. Axial Energy Distribution in Disc-Shaped Tantalum and Aluminium ...
  • Sofiienko A, Jarvis C, Ådne V. Electron range evaluation and ...
  • نمایش کامل مراجع