A Real-Time Heart Rate Signal Detection using an Electronic Stethoscope with Labview
محل انتشار: مجله فیزیک و مهندسی پزشکی، دوره: 10، شماره: 3
سال انتشار: 1399
نوع سند: مقاله ژورنالی
زبان: انگلیسی
مشاهده: 46
فایل این مقاله در 8 صفحه با فرمت PDF قابل دریافت می باشد
- صدور گواهی نمایه سازی
- من نویسنده این مقاله هستم
استخراج به نرم افزارهای پژوهشی:
شناسه ملی سند علمی:
JR_JBPE-10-3_015
تاریخ نمایه سازی: 30 دی 1402
چکیده مقاله:
Better accurate stethoscope measurements have been needed to diagnose heart problems earlier, monitor patients, and provide initial clinical data for physicians. This study aims to evaluate an electronic stethoscope for automatic identification of heart rate by monitoring Beats Per Minute (BPM) in real-time. In this work, a new design with a low cost electronic stethoscope is designed and implemented as a simple circuit for a replacement with conventional stethoscopes. This presented a low cost stethoscopes consisting of a preamplifier, low-pass filter, high-pass filter, microcontroller and Bluetooth. This simulation and experimental study was carried out for electronic circuit design testing. The condenser microphone transmited the signal into the signal conditioning circuit, and amplified it from ۱۰ to ۳۰ times. The low- and high- pass filter circuit was with cutoffs of ۱۸۰ Hz and ۵۰ Hz, respectively. The result shows that the fourth-order Butterworth filter was the best filter, with a gain of ۰.۷۰۷ Volt, -۳.۰۱ dB, and ۰.۷۸۲ Volt, -۲.۱۳۷ dB, respectively. The real-time measurements using the system are not significantly different from the manual measurements, with around ۲-۵%, with a delay of ۱.۷ to ۲ seconds. The results indicated that an electronic stethoscope system could provide suitable information for BPM value and could display heart sound signals.
کلیدواژه ها:
نویسندگان
P Oktivasari
MSc, Department of Physics, Institut Teknologi Bandung, Jl. Ganesha, Bandung
F Haryanto
PhD, Department of Physics, Institut Teknologi Bandung, Jl. Ganesha, Bandung
A Hamidah Salman
PhD, Electrical Engineering Department, Institut Teknologi Bandung, Jl. Ganesha, Bandung
R Riandini
MSc, Electrical Engineering Department, Politeknik Negeri Jakarta, Jakarta
S Suprijadi
PhD, Department of Physics, Institut Teknologi Bandung, Jl. Ganesha, Bandung
مراجع و منابع این مقاله:
لیست زیر مراجع و منابع استفاده شده در این مقاله را نمایش می دهد. این مراجع به صورت کاملا ماشینی و بر اساس هوش مصنوعی استخراج شده اند و لذا ممکن است دارای اشکالاتی باشند که به مرور زمان دقت استخراج این محتوا افزایش می یابد. مراجعی که مقالات مربوط به آنها در سیویلیکا نمایه شده و پیدا شده اند، به خود مقاله لینک شده اند :