Validation of the Gel & Wax Boluses and Comparison of their Dosimetric Performance with Virtual Bolus

سال انتشار: 1398
نوع سند: مقاله ژورنالی
زبان: انگلیسی
مشاهده: 38

فایل این مقاله در 8 صفحه با فرمت PDF قابل دریافت می باشد

استخراج به نرم افزارهای پژوهشی:

لینک ثابت به این مقاله:

شناسه ملی سند علمی:

JR_JBPE-9-6_006

تاریخ نمایه سازی: 30 دی 1402

چکیده مقاله:

Background: In general, radiotherapy treatment planning is performed using the virtual bolus. It is necessary to investigate physical bolus in comparison to virtual one. Objectives: In the present study, first, radiological properties of superflab Gel bolus and Paraffin wax bolus was investigated in terms of their relative electron density. Then, dosimetric performance of both the bolus (i.e. Gel and Parafin wax) was compared with Virtual bolus.Material and Methods: In This experimental study, the radiological property of Wax and Gel boluses was investigated using two methods. In one, the relative electron density of both the Gel and Wax boluses was calculated by measuring their linear attenuation coefficient where in another method relative electron density was calculated by recording their CT No directly from their CT scan. Later CT scan of solid water slab phantom (dimension ۳۰x۳۰x۱۵ cm۳), with physical boluses (i.e. Gel and Wax bolus) of appropriate thicknesses required to deliver a dose of ۲۰۰ cGy at Dmax using ۴ MV, ۶ MV and ۱۵ MV photon beams, was taken. These CT data sets were retrieved to TPS. A plan was done to deliver a dose of ۲۰۰ cGy at Dmax using Single ۴ MV, ۶ MV and ۱۵ MV photon beams. Dose at depths Dmax, ۱ cm, ۲ cm, ۳ cm, ۴ cm and ۵ cm was recorded. Using this similar method, doses at depths viz Dmax, ۱ cm, ۲ cm, ۳ cm, ۴ cm and ۵ cm was recorded for the Gel and Wax boluses. The differences in dose of gel and wax bolus from virtual bolus were recorded for comparison of their dosimetric performance. Results: The measured (calculated) relative electron density of wax and Gel bolus was found to be ۰.۹۵۸ (۰.۹۲۶) and ۰.۹۲۳ (۰.۹۰۷), respectively. Variation in dosimetric performance of Gel and Wax with reference to Virtual bolus was studied. However, on average, Gel bolus was more consistent with virtual bolus. Conclusion: To avoid any dose difference between, delivered (using physical bolus) and planned (using virtual bolus), the physical boluses should be investigated for their dosimetric performance in comparison to virtual bolus. The results obtained and methodology used in this study can be applied in routine radiotherapy practices.

کلیدواژه ها:

نویسندگان

T R Verma

PhD, Department of Radiotherapy, King George’s Medical University, UP, Lucknow, India

N K Painuly

PhD, Department of Radiotherapy, King George’s Medical University, UP, Lucknow, India

M Tyagi

MSc, Department of Radiology & Radiotherapy, UCMS, Delhi, India

D Johny

MSc, Department of Radiotherapy, King George’s Medical University, UP, Lucknow, India

R Gupta

MD, Department of Radiotherapy, King George’s Medical University, UP, Lucknow, India

M L B Bhatt

MD, Department of Radiotherapy, King George’s Medical University, UP, Lucknow, India

مراجع و منابع این مقاله:

لیست زیر مراجع و منابع استفاده شده در این مقاله را نمایش می دهد. این مراجع به صورت کاملا ماشینی و بر اساس هوش مصنوعی استخراج شده اند و لذا ممکن است دارای اشکالاتی باشند که به مرور زمان دقت استخراج این محتوا افزایش می یابد. مراجعی که مقالات مربوط به آنها در سیویلیکا نمایه شده و پیدا شده اند، به خود مقاله لینک شده اند :
  • El Shahat K, El Saeid A, Attalla E, Yassin A. ...
  • Catli S. High-density dental implants and radiotherapy planning: evaluation of ...
  • Kuwahata N, Fujita H, Yamanishi H, Okazaki E, Fukuda H. ...
  • Fujita H, Kuwahata N, Hattori H, Kinoshita H, Fukuda H. ...
  • Banaee N, Nedaie HA, Nosrati H, Nabavi M, Naderi M. ...
  • Tyran M, Tallet A, Resbeut M, Ferre M, Favrel V, ...
  • Humphries SM, Boyd K, Cornish P, Newman FD. Comparison of ...
  • Malaescu I, Marin CN, Spunei M. Comparative Study on the ...
  • Verma TR, Painuly NK, Mishra SP, Singh N, Bhatt MLB, ...
  • Kumar A, Sharma SD, Arya AK, Gupta S, Shrotriya D. ...
  • Brown S, Bailey DL, Willowson K, Baldock C. Investigation of ...
  • نمایش کامل مراجع