Human Health Risk Assessment of ۴-۱۲ GHz Radar Waves using CST STUDIO SUITE Software

سال انتشار: 1401
نوع سند: مقاله ژورنالی
زبان: انگلیسی
مشاهده: 54

فایل این مقاله در 12 صفحه با فرمت PDF قابل دریافت می باشد

استخراج به نرم افزارهای پژوهشی:

لینک ثابت به این مقاله:

شناسه ملی سند علمی:

JR_JBPE-12-3_008

تاریخ نمایه سازی: 30 دی 1402

چکیده مقاله:

Background: The application of radar systems in telecommunications and aerospace science is important. However, engineering department’s staff various tissues are always under chronic radiation generated by the radar fields which may affect health. Objective: This study aims to evaluate the risk of radar wave exposure and to explore the effects and limitations.Material and Methods: In this simulation study, an adult body model versus ۱ watt source with a distance of ۵۰ centimeters exposure has been simulated using the CST STUDIO SUITE. Furthermore, various physical and electrical properties of each tissue and organ for different frequencies and exposure times have been studied. The exposure dose limitations have been considered using the International Commission on Non-Ionizing Radiation Protection (ICNIRP) safety and health guide report. Results: Total body absorbed doses for ۴ GHz, ۸ GHz, and ۱۲ GHz frequency, and ۶ min, ۴ h, and ۳۰ days exposure time, have been calculated as ۱.۱۳۶×۱۰-۵, ۱.۵۹۸×۱۰-۵, ۱.۵۸×۱۰-۳, ۱.۵۲۱×۱۰-۵, ۳.۱۲۲×۱۰-۵, ۴.۵۲×۱۰-۳, ۴.۱×۱۰-۵, ۱۰-۴, and ۱۰-۲, respectively. Conclusion: It has shown that the internal organs of the body and head will be under more risk by reducing radar frequencies from ۱۲ GHz to ۴ GHz. On the other hand, the higher frequency can cause a higher risk to the human skin. In addition, the maximum Specific Absorption Rate (SAR) for each case has been calculated. The results show that for this normalized source, the safety criteria have been respected, but for a higher source, the calculations must be repeated.

نویسندگان

- -

MD, Emam Sajad Hospital Clinical Research Center, Yasuj University of Medical Sciences, Yasuj, Iran

- -

PhD, Department of Physics, Center of Basic Science, Khatam ol-Anbia (PBU) University, Tehran, Iran

- -

MSc, Atomic and Molecular Group, Faculty of Physics, University of Kashan, Kashan, Iran

- -

PhD, Department of Physics, Center of Basic Science, Khatam ol-Anbia (PBU) University, Tehran, Iran

مراجع و منابع این مقاله:

لیست زیر مراجع و منابع استفاده شده در این مقاله را نمایش می دهد. این مراجع به صورت کاملا ماشینی و بر اساس هوش مصنوعی استخراج شده اند و لذا ممکن است دارای اشکالاتی باشند که به مرور زمان دقت استخراج این محتوا افزایش می یابد. مراجعی که مقالات مربوط به آنها در سیویلیکا نمایه شده و پیدا شده اند، به خود مقاله لینک شده اند :
  • Madhukar A, Park Y, Kim W, Sunaryanto HJ, Berlin R, ...
  • Foster K, Colombi D. Thermal response of tissue to RF ...
  • Sasaki K, Mizuno M, Wake K, Watanabe S. Monte Carlo ...
  • Gabriel C, Peyman A. Chapter ۶۹ - Dielectric Properties of ...
  • Ziskin MC, Alekseev SI, Foster KR, Balzano Q. Tissue models ...
  • Gupta A, Verma S, Mani KV, Keshri GK, Karmakar S, ...
  • Momoli F, Siemiatycki J, McBride ML, Parent M-É, Richardson L, ...
  • Thomas G, Symonds P. Radiation exposure and health effects–is it ...
  • Belyaev I. Dosimetry in Bioelectromagnetics: Duration of exposure and dose ...
  • Tavakoli M, Mansouri M, Jahantigh F. Reliability analysis of free ...
  • Li W, Tan B, Piechocki R. Passive radar for opportunistic ...
  • Sharma A, Kesari KK, Saxena VK, Sisodia R. Ten gigahertz ...
  • Williams PM, Fletcher S. Health effects of prenatal radiation exposure. ...
  • Peleg M, Nativ O, Richter ED. Radio frequency radiation-related cancer: ...
  • Movahedi MM, Tavakkoli-Golpayegani A, Mortazavi SAR, Haghani M, Razi Z, ...
  • Mortazavi SMJ, Mosleh-Shirazi MA, Tavassoli AR, Taheri M, Mehdizadeh AR, ...
  • Mortazavi SMJ, Motamedifar M, Mehdizadeh AR, Namdari G, Taheri M. ...
  • Taheri M, Mortazavi SMJ, Moradi M, Mansouri Sh, et al. ...
  • Mahmoudi R, Mortazavi SMJ, Safari S, Nikseresht M, Mozdarani H, ...
  • Wdowiak A, Mazurek PA, Wdowiak A, Bojar I. Effect of ...
  • Garripoli C, Mercuri M, Karsmakers P, Soh PJ, Crupi G, ...
  • Kazemi S, Ghorbani A, Amindavar H. Cyclostationary modelling of amplitude ...
  • Lee YS, Pathirana PN, Steinfort CL, Caelli T. Monitoring and ...
  • Alemaryeen A, Noghanian S, Fazel-Rezai R. Antenna Effects on Respiratory ...
  • Amin MG, Zhang YD, Ahmad F, Ho KD. Radar signal ...
  • Kranjec J, Beguš S, Drnovšek J, Geršak G. Novel methods ...
  • Barnes F, Greenenbaum B. Some Effects of Weak Magnetic Fields ...
  • Nakagawa H, Ohuchi M. Virtual blood-flow controlling system: Optimization of ...
  • Bao Q, Peng X, Wang Z, Lin Y, Hong W. ...
  • Tang A, Reck T, Chattopadhyay G. CMOS system-on-chip techniques in ...
  • Zhadobov M, Nicolaz CN, Sauleau R, Desmots F, Thouroude D, ...
  • Basak T, Aparna K, Meenakshi A, Balakrishnan A. Effect of ...
  • Zhang K, Huang J, Xu X, Guo Q, Chen Y, ...
  • Mutalik S, Mat M, Zakaria M, Yusoff M. A Study ...
  • Wessapan T, Srisawatdhisukul S, Rattanadecho P. Numerical analysis of specific ...
  • Gosselin M-C, Vermeeren G, Kuhn S, Kellerman V, Benkler S, ...
  • نمایش کامل مراجع