The Accuracy of Sanitary Pad of Nitrazine Test in the Diagnosis of Premature Rupture of Membranes

سال انتشار: 1397
نوع سند: مقاله ژورنالی
زبان: انگلیسی
مشاهده: 34

متن کامل این مقاله منتشر نشده است و فقط به صورت چکیده یا چکیده مبسوط در پایگاه موجود می باشد.
توضیح: معمولا کلیه مقالاتی که کمتر از ۵ صفحه باشند در پایگاه سیویلیکا اصل مقاله (فول تکست) محسوب نمی شوند و فقط کاربران عضو بدون کسر اعتبار می توانند فایل آنها را دریافت نمایند.

استخراج به نرم افزارهای پژوهشی:

لینک ثابت به این مقاله:

شناسه ملی سند علمی:

JR_IJHS-4-4_006

تاریخ نمایه سازی: 29 بهمن 1402

چکیده مقاله:

Background: Sanitary Pad of Nitrazine Test (SPONT) is one of the newest method to diagnosis premature rupture of membranes (PROM) that doesn't need women attending hospital and applying speculum. The aim of this study was to assess the performance of SPONT versus standard clinical assessment.Methods: A prospective diagnostic accuracy study, ۱۴۰ pregnant women with symptoms of PROM in ۲۲-۴۲ weeks of gestation were involved. The accuracy of SPONT in the diagnosis of PROM was compared with Nitrazine, Fern and Pooling tests that were performed at the same time.Results: The sensitivity, specificity, positive predictive value, and negative predictive value of SPONT, routine Nitrazine, Fern and Pooling tests were ۹۳.۲%, ۸۵.۷%, ۹۷.۳%, ۶۹.۲%; ۹۴.۱%, ۹۰.۵%, ۹۸.۲% ۷۳.۱%; ۸۰.۱%, ۹۵.۲%, ۹۸.۹%, ۴۶.۵%; and ۶۸.۱%, ۹۵.۲%, ۹۸.۹% ۴۶.۵%, respectively. The sensitivity of SPONT was the same as routine Nitrazine test (P.V=۰.۸۱۱). SPONT has higher sensitivity than Fern test (P.V=۰.۰۰۸) and Pooling test (P.V<۰.۰۰۱). The accuracy of the applied tests was ۹۲.۱%, ۹۳.۶%, ۸۲.۸% and ۷۲.۸% respectively for SPONT, Nitrazine, Fern and Pooling tests. There wasn't significant difference between accuracy of SPONT and standard clinical assessment (۹۲.۱% vs. ۸۹.۳%).Conclusions: The accuracy of SPONT was the same as routine Nitrazine test in PROM diagnosis that pregnant women can use it if they do not have immediate access to health centers.Background: Sanitary Pad of Nitrazine Test (SPONT) is one of the newest method to diagnosis premature rupture of membranes (PROM) that doesn't need women attending hospital and applying speculum. The aim of this study was to assess the performance of SPONT versus standard clinical assessment. Methods: A prospective diagnostic accuracy study, ۱۴۰ pregnant women with symptoms of PROM in ۲۲-۴۲ weeks of gestation were involved. The accuracy of SPONT in the diagnosis of PROM was compared with Nitrazine, Fern and Pooling tests that were performed at the same time. Results: The sensitivity, specificity, positive predictive value, and negative predictive value of SPONT, routine Nitrazine, Fern and Pooling tests were ۹۳.۲%, ۸۵.۷%, ۹۷.۳%, ۶۹.۲%; ۹۴.۱%, ۹۰.۵%, ۹۸.۲% ۷۳.۱%; ۸۰.۱%, ۹۵.۲%, ۹۸.۹%, ۴۶.۵%; and ۶۸.۱%, ۹۵.۲%, ۹۸.۹% ۴۶.۵%, respectively. The sensitivity of SPONT was the same as routine Nitrazine test (P.V=۰.۸۱۱). SPONT has higher sensitivity than Fern test (P.V=۰.۰۰۸) and Pooling test (P.V<۰.۰۰۱). The accuracy of the applied tests was ۹۲.۱%, ۹۳.۶%, ۸۲.۸% and ۷۲.۸% respectively for SPONT, Nitrazine, Fern and Pooling tests. There wasn't significant difference between accuracy of SPONT and standard clinical assessment (۹۲.۱% vs. ۸۹.۳%). Conclusions: The accuracy of SPONT was the same as routine Nitrazine test in PROM diagnosis that pregnant women can use it if they do not have immediate access to health centers.

کلیدواژه ها:

Nitrazine ، Premature ruptures of membrane ، Diagnostic test ، Accuracy ، PROM

نویسندگان

Arezoo Haseli ۱*

۱. Student Research Committee, School of Nursing and Midwifery, Shahroud University of Medical Sciences, Shahroud, Iran.

Bahare Afshar ۲

۲. Student Research Committee, School of Nursing and Midwifery, Iran University of Medical Sciences, Tehran, Iran.